Quantcast
Channel: THWACK: All Content - Server & Application Monitor
Viewing all articles
Browse latest Browse all 12281

Weird results when testing an HTTPS Monitor

$
0
0

I just built a new HTPS Monitor, and put it into a standard SAM Template.

 

When I assign a test node to the Component Monitor in the template, and run the test, I get the following error:

Error:

 

Server stack trace:

 

   at System.ServiceModel.Channels.SecurityChannelFactory`1.SecurityRequestChannel.ProcessReply(Message reply, SecurityProtocolCorrelationState correlationState, TimeSpan timeout)

 

   at System.ServiceModel.Channels.SecurityChannelFactory`1.SecurityRequestChannel.Request(Message message, TimeSpan timeout)

 

   at System.ServiceModel.Security.SecuritySessionSecurityTokenProvider.DoOperation(SecuritySessionOperation operation, EndpointAddress target, Uri via, SecurityToken currentToken, TimeSpan timeout)

 

   at System.ServiceModel.Security.SecuritySessionSecurityTokenProvider.GetTokenCore(TimeSpan timeout)

 

   at System.IdentityModel.Selectors.SecurityTokenProvider.GetToken(TimeSpan timeout)

 

   at System.ServiceModel.Security.SecuritySessionClientSettings`1.ClientSecuritySessionChannel.OnOpen(TimeSpan timeout)

 

   at System.ServiceModel.Channels.CommunicationObject.Open(TimeSpan timeout)

 

   at System.ServiceModel.Channels.ServiceChannel.OnOpen(TimeSpan timeout)

 

   at System.ServiceModel.Channels.CommunicationObject.Open(TimeSpan timeout)

 

   at System.ServiceModel.Channels.ServiceChannel.CallOpenOnce.System.ServiceModel.Channels.ServiceChannel.ICallOnce.Call(ServiceChannel channel, TimeSpan timeout)

 

   at System.ServiceModel.Channels.ServiceChannel.CallOnceManager.CallOnce(TimeSpan timeout, CallOnceManager cascade)

 

   at System.ServiceModel.Channels.ServiceChannel.Call(String action, Boolean oneway, ProxyOperationRuntime operation, Object[] ins, Object[] outs, TimeSpan timeout)

 

   at System.ServiceModel.Channels.ServiceChannelProxy.InvokeService(IMethodCallMessage methodCall, ProxyOperationRuntime operation)

 

   at System.ServiceModel.Channels.ServiceChannelProxy.Invoke(IMessage message)

 

 

 

Exception rethrown at [0]:

 

   at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)

 

   at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)

 

   at SolarWinds.JobEngine.IJobScheduler.AddJob(ScheduledJob jobConfiguration)

 

   at SolarWinds.JobEngine.Routing.JobRouterWCFProxy.<>c__DisplayClass2.<AddJob>b__0(IJobExecutionRouterProxy n)

 

   at SolarWinds.JobEngine.WCFUtils.ChannelProxy`1.Invoke[TResult](Func`2 fnc, ChannelProxyBehavior behavior)

 

   at SolarWinds.JobEngine.WCFUtils.ChannelProxy`1.Invoke[TResult](Func`2 fnc)

 

   at SolarWinds.JobEngine.Routing.JobRouterWCFProxy.AddJob(ScheduledJob jobConfiguration)

The icon underneath the test node indicates is still running, and never finishes.

 

However, if I Submit it, and allow the Application Monitor to run, it sees the webpage, no problem, and does not log an error. Once this started, it is now doing it to other Templates that were previously working.

 

What is this error from? How can I make it so that I can run tests in the Template Wizard again?

 

Thanks

 

EDIT: This is happening on ALL Application Monitor tests, it turns out. I have some PowerShell and service monitors, and they are giving the same result when I try to run a test.