SAM v6.2 Hot Fix 1 is now available

$
0
0

This hotfix addresses and corrects a problem with the following:

 

  • Issue with alerts not containing details about processes from monitored nodes:
    • High CPU Utilization with Top 10 Processes
    • High Physical Memory Utilization with Top 10 Processes
    • High Virtual Memory Utilization with Top 10 Processes

 

  • Issue with SSL Expiration Date probe datetime parsing.


http://downloads.solarwinds.com/solarwinds/Release/HotFix/SAM-v6.2-HotFix1.zip

 

To install this hotfix:

-----------------------

1. If not updated already, upgrade the main poller and all additional pollers to version 6.2

2. On the main poller, install this hotfix by running the attached SAM-v6.2-HotFix1.exe and follow the on-screen instructions.

                a. Complete the Configuration Wizard.

3. On each additional poller, install this hotfix by running the attached SAM-v6.2-HotFix1.exe and follow the on-screen instructions.

                a. Complete the Configuration Wizard.

 

This hotfix modifies the following file on the SAM server:

----------------------------------------------------------

* C:\Program Files (x86)\SolarWinds\Orion\APM\SolarWinds.APM.RealTimeProcessPoller.exe

* C:\Program Files (x86)\SolarWinds\Orion\APM\SolarWinds.APM.Probes.dll

 

 

===========================================================

Only apply the following if you have upgraded from SAM 6.2RC1 to SAM v6.2 RTM, RC2 did not have this issue:

The following instructions will manually fix the following alerts if you upgraded from SAM v6.2 RC1:

 

- High CPU Utilization with Top 10 Processes

- High Physical Memory Utilization with Top 10 Processes

- High Virtual Memory Utilization with Top 10 Processes

 

After installing Hotfix 1 in SAM v6.2 RTM, take the following steps:

1. Open the web console and navigate to Settings > Manage Alerts.

2. Locate the alerts in question and edit each of them accordingly.

Note: If you are asked to create a copy, disable the original alert before creating it to avoid duplicate notifications

 

a. In TRIGGER ACTIONS, edit the first action called Execute program : APM\SolarWinds.APM.RealTimeProcessPoller.exe -n${NodeId}... (the parameters may vary).

b. In the Configure Actions dialog box, modify the Network path to external program field and replace "-alert=${AlertDefID}" with "-alertid=${N=Alerting;M=AlertID}".

c. Save the changes and do the same for all other affected alerts.

 